| Microplate
Luminometer - Catalog # MPL1 |
|
The
MPL1 Microplate Luminometer is an
affordable but high quality instrument
with basic functionality.
It incorporates all important
functions necessary to perform
glow luminescence measurements
and it is suitable for all applications
which require a very high dynamic
range, but not extremely high sensitivity.
Due to the concentration on the
few critical functionalities, the
instrument is available for a very
attractive price. CE certified.
|
| Microplate Luminometer - Catalog # Lumi |
 |
- Detection Mode, Glow luminescence
- Vessel, Single, double, or break
apart strips, up to 12 wells,36 well
loading capacity
- Plate Format,Common strip carrier
can hold three12- well strips or
three 8-well strips
- Range 106
- Cross talk Less than 2.5 x 10-4
- Detector Photomultiplier (PMT)
Spectral
- Response Range 300-650 nm
- Peak Wavelength 400 nm
- Sensitivity/Detection limit HRP
1-18 x 10, LinearDynamic, -21ALP
1x10, other tests pending
|
| Microplate
Reader - Catalog #SF 2100 |
 |
Fully
Automatic. Bichromatic optics. Standard
model includes four filters; six
filters are available for a nominal
charge. Onboard data reduction calculations
include regressions, curve fitting
and cutoff absorbance calculations
with step-by-step user prompting.
Large, non-volatile memory stores
at least 50 user tests. Includes
parallel and serial outputs. Operates
with or without a computer. A bi-directional
accessory is available for linking
to IBM compatible computer. NRTL
and CE certified.
|
| Incubator/Shaker
- Catalog #SF 2200 |
 |
Stat Fax 2200 Incubator/Shaker
Holds two 96 well microplates. Digitally
controlled 8-speed shaker with
orbital mixing from 575 to 1500
rpm. Temperature adjustable from
ambient to 40°C with resolution
of 0.1°C.
Digital timer controls shaking
or can be operated independently
as a timer. Compact and easy to
operate. Outer tinted cover provides
further insulation and protection
from light. NRTL and CE certified.
|
| Incubator/Shaker
- Catalog #SF 303 |
 |
Stat
Fax 303+Microstrip Reader
Automatic strip transportation. 3-strip
loading capacity or break-apart, single,
and double strips. The carriers come
in two styles, 3x12 for break-apart
microwell strips, and an optional 3x8
for non-break-apart microwell strips.
Bichromatic optics.
Standard model includes four filters;
six filters are available for a
nominal charge. Easy to use with
step-by-step prompting and on-board
graphics printer, log-logit mode
and other programming enhancements.
On-board software calculates single & multi-point
calibration curves, regressions & a
variety of cutoff options. Large
non-volatile memory stores more
than 50 user entered tests. NRTL
and CE certified Microplate Washer
Catalog # SF 2600
|
| Microplate
Washer - Catalog #SF 2600 |
 |
Stat
Fax 2600 Microplate Washer
Fully automatic. Washes flat, round,
V-bottom plates and strips. No user
adjustments required. Automatic calibration,
alignment, and last row detection.
Large, non-volatile memory stores
at least 50 user wash protocols,
Precision operation with constant
monitoring of vacuum and pressure.
Pump cycles only when necessary
for quiet operation. Programmable
automatic rinse cycle. Ready to
run: bottles, aerosol shield, 8-way
manifold included. 12 and 16 position
wash heads available as accessories.
NRTL and CE certified.
|
| Microplate
Reader and Printer- Catalog #SF 3200P |
 |
3200P
Stat Fax 3200 Microplate Reader
with optional on-board printer Fully
automatic. Bichromatic optics.
Standard model includes four filters;
six filters are available for a
nominal charge.
On-board data reduction calculations
include regressions, curve fitting
and cut off absorbance calculations
with step-by-step user prompting.
Large, non-volatile memory stores
over 100 user tests. Includes parallel
and serial outputs. New larger
display with graphics capability.
Optional on-board printer. NRTL
and CE certified.
|
| Stat
Wash Microwell Washer - Catalog # SF3100 |
 |
No more
squirt bottle washing. Reduce exposure
to the potential dangers of splashing
biohazards with Stat Wash™,
an economical instrument designed
to wash immunoassays in microwell
strips and plates with professional
precision.
Washing 8 wells simultaneously
is faster too. Aspirating and dispensing
are controlled by push buttons.
Easy to use and maintain, Stat
Wash™ includes an 8-probe
manifold, a 1L wash bottle, and
a 1L safe plastic bottle with a
full sensor. Stat Wash™ is
CE Certified.
|
| Stat
Fax Chemistry Analyzer - Catalog #
SF1904P |
 |
Chemistry
Analyser Catalog # SF1904P
Bichromatic optics. Six filters standard.
Easy to use with step-by-step prompting
and on-board graphics printer. 12 station
37°C incubation block and temperature
controlled read well.
Cuvette size is 12mm by 75mm.
Performs both end point and kinetic
assays. Large non-volatile memory
stores approximately 60 user programs.
With Mosquito ™ flowcell
accessory you can read volumes
as small as 250 microliters.
CE certified. |
| Stat Fax Chemistry Analyzer - Catalog # SF 3300 |
 |
- Stability:
Drift of no more than 0.005 A in
8 hours
- Tube of Cuvette: -0.2 to -2.5
absorbance
- Filter Types: Ultra Long Life
Multiple Cavity IAD hard Coat
- Processor: z180
- Program Memory: 1 Megabit
- RAM:32K Byte
- Iluminated Volume: 21 Ul
- Aspiration Volume: Programmable
250Ul-750Ul
- Optional External Heat Block:
18 Wells, Controlled Temp @37º C
- Optional Read Cell Cooling: Peltier
Cooling System-Cell Only
|